Anritsu's high precision Capsule Checkweighers weigh 100% capsules reliably at high speed.
It is equipped with the newly developed capsule handling mechanisms which ensure highly reliable capsule feeding, weighing, and rejection. Anritsu's force balance weighing technology provides the industry's highest weighing accuracy of ± 0.5 mg, contributing to more advanced quality control and improved production efficiency.
- Best weighing solution for capsules containing active pharmaceutical ingredients
Anritsu's force balance technology provides the maximum weighing accuracy of ±0.5 mg, meeting even the most stringent standards for cuspules such as anticancer drugs and immunosuppressive drugs, in which only small changes in quantity could affect both intended effects and side effects.
- Contribution in yield improvement
High-precision weighing enables you to set the upper and lower limits of the checkweigher closer to the permissible weight limits for your product quality control standard. As a result, the ratio of non-defective products will increase, contributing to improved production efficiency and reduction of raw material costs.
- 3 models are available according to the production scale
The most compact 10-lane model can process up to 75,000 capsules/hour, while 30-lane model can candle maximum 230,000 capsules/hour.
You can select the best suitable model depending on the production volume.
- The most reliable capsule handling system
Capsules placed in the inlet hopper are divided into multiple lanes by the magazine and transported, weighed and sorted at high speed.
The newly developed handling mechanism has significantly improved reliability and environmental flexibility in capsule handling.
It can handle a variety of capsules, including filled and empty capsules.
The feeding mechanism is easy on capsules as it reduces static electricity, and also ensures precise inspections and reliably rejects improper weight products.
- Enhanced fail-safe mechanisms
In case of unexpected malfunction and troubles
If the power is cut off due to a power outage or lightning strike and the measurement becomes impossible, both the rejection and the exclusion gate immediately operate to eliminate all the capsules being transported and do not transport them to the subsequent stage.
- Enhanced safety with interlock system
The panels covering the magazine and conveyor are fully transparent and have no blind spots. Good visibility facilitates checking for residual capsules, helping to prevent cross contamination. The covers can be opened and closed without tools. If any cover is open, the equipment is stopped with the interlock for safe operation.
- Quick, tool-free part exchange
The parts for each capsule size can be attached and detached without tools. The magazine and conveyor are easily accessible and can be held firmly with both hands. Compared to the previous model, the number of parts has been reduced, which decreases the changeover time to one minute or less.
- Conforming to international industry standards and regulations
The system supports user authentication, audit trails, and data encryption/decryption required by FDA 21 CFR Part 11 (optional).
The parts in contact with capsules are made of materials compliant with FDA 21 CFR Part177. (The material certificate and the processing certificate are available.)

Download
- Download our comprehensive Food, Pharmaceutical & Industrial Solutions Catalogue here.